Abstract

Background: Diagnostic reference levels (DRLs) support dose optimisation, but differences in patient selection, technology and dosimetry complicate comparisons in adult posteroanterior (PA) chest radiography. Purpose: To provide a focused, method-aware synthesis of published reference values and their practical interpretation. Methods: The existing narrative evidence base was supplemented on 6 October 2026 by targeted web searches for PubMed/PMC records, publisher pages and official radiation-protection guidance. Recent evidence published from January 2020 to the search date was prioritised, with earlier foundational guidance retained. Projection, patient size, detector technology, dose quantity, measurement approach and statistical basis were extracted where accessible. Results: Selected studies reported surface-dose/kerma reference values of 0.20–0.68 mGy, which are not automatically equivalent quantities. PA chest kerma-area-product values included 51 mGy·cm² in Dubai, 77 mGy·cm² in the UK and 769.23 mGy·cm² in the Korean equipment survey. These differences cannot be interpreted as a ranking because the studies differ in sampling, dosimetry and reference-level derivation. Conclusion: The practical contribution is a comparability checklist and an investigation pathway linking dose variation to patient size, equipment, exposure technique, measurement uncertainty and diagnostic image quality. DRLs should guide group-level investigation and iterative optimisation, rather than serve as individual patient limits or universal dose targets.

References

1. Vañó E, Miller DL, Martin CJ, Rehani MM, Kang K, Rosenstein M, Ortiz-López P, Mattsson S, Padovani R, Rogers A. Diagnostic reference levels in medical imaging. ICRP Publication 135. Ann ICRP. 2017;46(1):1–144.

2. International Commission on Radiological Protection. Managing patient dose in digital radiology. ICRP Publication 93. Ann ICRP. 2004;34(1):1–75.

3. Dave JK, Jones AK, Fisher R, Hulme K, Rill L, Zamora D, Woodward A, Brady S, MacDougall RD, Goldman L, Lang S, Peck D, Apgar B, Shepard SJ, Uzenoff R, Willis C. Current state of practice regarding digital radiography exposure indicators and deviation indices: Report of AAPM Imaging Physics Committee Task Group 232. Med Phys. 2018;45(11):e1146–e1160. doi:10.1002/mp.13212.

4. Martin CJ, Applegate K, Hernandez-Giron I, Husseiny D, Kortesniemi M, Del Rosario Perez M, Sutton DG, Vassileva J. Optimisation of radiological protection in digital radiology techniques for medical imaging. ICRP Publication 154. Ann ICRP. 2023;52(3):11–145.

5. International Atomic Energy Agency. Dosimetry in diagnostic radiology: an international code of practice. Technical Reports Series No. 457. Vienna: IAEA; 2007.

6. Petoussi-Henss N, Zankl M, Drexler G, Panzer W, Regulla D. Calculation of backscatter factors for diagnostic radiology using Monte Carlo methods. Phys Med Biol. 1998;43(8):2237–2250.

7. Jibiri NN, Olowookere CJ. Evaluation of dose-area product of common radiographic examinations towards establishing a preliminary diagnostic reference levels (PDRLs) in Southwestern Nigeria. J Appl Clin Med Phys. 2016;17(6):392–404. doi:10.1120/jacmp.v17i6.6011.

8. Schegerer AA, Stamm G, Aberle C, Ammon J, Bazrafshan B, Borowski M, Eßeling R, Madsack B, Menz R, Müller C, Oberhofer N, Renger B, Singer J, Verius M, Walz M, Jungnickel K. International survey on diagnostic reference levels based on clinical indications in plain radiography. Eur Radiol. 2025;35(6):3336–3346. doi:10.1007/s00330-024-11224-2.

9. Abbeyquaye D, Inkoom S, Dery TB, Issahaku S, Ohene-Botwe B. National diagnostic reference levels in general radiography: a scoping review. J Med Phys. 2025;50(2):207–216.

10. Ahmed NA, Basheir EH, Farah AB, Mohammedzein TS, Suliman II. Proposed national diagnostic reference levels for standard radiographic X-ray procedures in Sudan. Radiat Prot Dosimetry. 2020;190(4):419–426. doi:10.1093/rpd/ncaa114.

11. Junda M, Muller H, Friedrich-Nel H. Local diagnostic reference levels for routine chest X-ray examinations at a public sector hospital in central South Africa. Health SA Gesondheid. 2021;26:a1622. doi:10.4102/hsag.v26i0.1622.

12. Yoon YS, Park HM, Won JH, Song SK, Gil JW, Lee BY. Korean diagnostic reference level for general radiography and mammography in 2022. Public Health Wkly Rep. 2023;16(31):1082–1100. doi:10.56786/PHWR.2023.16.31.2.

13. Arriaga A, Gonçalves C, Teles P, Santos J, Simãozinho P, Sousa P. Establishment of local diagnostic reference levels for abdomen and chest radiographies in the region of Algarve, Portugal. Eur J Radiol. 2024;170:111248. doi:10.1016/j.ejrad.2023.111248.

14. Dalah EZ, Zarooni MMA, Binismail FY, Beevi HA, Siraj M, Pottybindu S. Typical and local diagnostic reference levels for chest and abdomen radiography examinations in Dubai health sector. J Imaging. 2025;11(1):21. doi:10.3390/jimaging11010021.

15. UK Health Security Agency. National diagnostic reference levels (NDRLs) from 11 December 2025. London: UKHSA; 2025. Available from: https://www.gov.uk/government/publications/diagnostic-radiology-national-diagnostic-reference-levels-ndrls/ndrl (accessed 6 October 2026).

16. Aumalikova M, Nurseitova B, Kashkinbayev Y, Bakhtin M, Aisauyt M, Ibrayeva D, Kusherbayev N, Ilbekova K. Local diagnostic reference levels for routine chest X-ray examinations: first pilot study in Kazakhstan. Z Med Phys. 2026. doi:10.1016/j.zemedi.2026.02.003.

17. Launders JH, Cowen AR, Bury RF, Hawkridge P. Towards image quality, beam energy and effective dose optimisation in digital thoracic radiography. Eur Radiol. 2001;11(5):870–875.

18. European Commission. European guidelines on quality criteria for diagnostic radiographic images. Luxembourg: European Commission; 1996. EUR 16260 EN.

19. Ncwane V, Gumede L, Van Wyk B. Radiographers’ awareness, understanding, and implementation of diagnostic reference levels in medical imaging: a scoping review. J Med Imaging Radiat Sci. 2025;56(6):102101. doi:10.1016/j.jmir.2025.102101.

20. International Atomic Energy Agency. Radiation protection and safety in medical uses of ionizing radiation. IAEA Safety Standards Series No. SSG-46. Vienna: IAEA; 2018.

21. International Atomic Energy Agency. Radiation protection and safety of radiation sources: international basic safety standards. IAEA Safety Standards Series No. GSR Part 3. Vienna: IAEA; 2014.

22. European Commission. Diagnostic reference levels in thirty-six European countries. Radiation Protection No. 180, Part 2. Luxembourg: Publications Office of the European Union; 2014.

23. Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M. Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology. 2008;248(1):254–263.

Downloads

Published

2026-10-07

Issue

Section

Review Article

How to Cite

Patient Dose Assessment and Diagnostic Reference Levels in Routine Adult PA Chest Radiography: A Narrative Review. (2026). New Journal of Biology and Medicine, 2(3), 42-48. https://doi.org/10.64354/p84hq190

Similar Articles

1-10 of 19

You may also start an advanced similarity search for this article.